COMPOSITIONS
Down the main page


Produced colors
Publications about [UNIPOL]®
Comparative tables
Technical descriptions
Stamp OF THE AM
Stamp AP
Stamp AT
Stamp ATs
Stamp B
Stamp [v]
Stamp [VU]
Stamp V -[Se]
Stamp [VE]
[Unipol] [GU]
Stamp [PV]
Stamp T
[Unipol] XO
[Unipol] the waterproofing
[Unipol] ground
Catalog of the production
Instructions beyond the putting
Forms of the agreements
Questions and the answers
on-line- consultation



Managers:
ICQ 432360199432360199 Julia
SEARCH ON THE SITE:

Information

Chemically resistant priming enamel [SBE]-111 [UNIPOL]® stamp [v]

Priming enamel [SBE]-111 [UNIPOL]® stamp [v] forms chemically resistant coating to the majority of highly aggressive media, including to the inorganic acids of average and high concentrations (sulfuric, salt, phosphoric, hydrofluoric and the like). Priming enamel is intended for the corrosion protection of metallic and ferroconcrete constructions, conduits, internal and external surfaces of capacities, which work before the aggressive media.

Index Value
Connecting basis: Natural rubber- epoxy
Composition Two-component; 1:1 as far as the volume
The dry residue: Not less than 50%
The relative viscosity of enamel at a temperature (20±0,5) of °C on the viscosimeter of the type Of [v]3-246 (or [VZ]-4) with the diameter of nozzle 4 mm: Is not less than 110 s
Degree of the grinding: Not are more than 50 m
Color: Any about the agreement for the sake of the customer or on catalog RAL
Degree of the dilution: 10% of the total volume
Storage Not to heat. To take care from the fire. Composition to store before the solidly closed container, protecting from the action of heat, the straight lines of the solar of rays and moisture. Guarantee period of storage before the hermetically sealed container of manufacturing plant - twelve months based on the day of production.
Diluents: Xylene, solvent, toluene
Putting: By brush, by roller, by the methods pneumo- and airless dispersion
Quantity of the layers: 4-6 depending on the aggressiveness of the medium
Expenditure and the thickness of the coating: With the recommended thickness of coating 300-500[mkm]
The theoretical flow rate ~ of 0,66-1,1 [kg]/[m]2
Putting conditions Priming enamel is allowed to bring with the ambient temperature and painted surface from 0o[S] to 35o[S] and the high relative humidity of air.
Viability with (20±2) o[S], ch, not less 4 hours after the mixing of the components
The time of drying the coating with a thickness of 80 m at a temperature (20±2) of o[S] and [f]=65% down the degree “of 3” according to GOST 19007, is not more 1 the hour
The complete set of the physicomechanical properties of coating at a temperature of 20oC and relative humidity of air 65% 10-12 days

Index Value
The exterior view of the coating Uniform lusterless surface without the foreign inclusions
Wear resistance of coating according to GOST 20811-75 (method a) 3,3 kgf/m
Strength of film with the bend not more than 1 mm
Adhesion, according to GOST 15140-78 method 2 is not more than 1 mark
Strength of film with the impact not less than 50 cm
Hiding power of the dried coating not more than 60 [g]/[m]2
Hardness about the pendulum gravimeter M-3 not less than 0,3 conv. un.
The resistance of film to static action by 96% of solution of sulfuric acid with (20±5)°[S], the thickness of coating is 500 m not less than 48 hours
The resistance of film to static action by 37% of solution of hydrochloric acid with (20±5)°[S], the thickness of coating is 500 m not less than 48 hours
The resistance of film to the static action of the concen. of the solution of orthophosphoric acid with (20±5)°[S], the thickness of coating is 500 m not less than 48 hours

Surface preparation

Basis Surface preparation
C[tal]: down the degree of cleaning S[a] 2,5 (ISO 8501-1)
Concrete surface On SNIP (Construction norms and regulations) 3.04.03 (see instruction beyond the putting)

Safety engineering:

With conducting of internal work, and after their end thoroughly to also air accomodation. To use individual protective means (TU 2312-001-59846005-2003).

The authenticity of present data is based beyond the laboratory tests and the practical experience. As supplier firm cannot bear responsibility for the damage, substituted by the application of material not in accordance with the given out by firm instruction beyond the application or with the use about the incorrect designation. Each individual case of applying the material is individual. Specifications description does not free based on fulfilling of the acting normative requirements of construction legislation. This technical description loses force after the appearance of a new editorial staff of text. The reprinting of texts and illustrations, the quoting of materials are allowed only by written authorization of the authors.

To unseal the page

Home Sitemap Contact us

Trusted site that we recommend to visit are:
Alveo , house rental , Miss anne hathaway films., wire-wrap jewelry , projekty domów , Amber Jewelry